EasyManua.ls Logo

Pomac Pumps PLP - 8 Closing down; Dismantling; Storage; Disposal

Pomac Pumps PLP
65 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User manual Pomac PLP Lobe pump
42 CE/PLP (1406) EN-12
8. Closing down
8.1. Dismantling
See paragraph 7.6 for dismantling instructions.
8.2. Storage
If the pump is going to be stored, the pump shaft must be rotated manually once a month.
If the pump is to be stored for a long period of time, it must be done so on a vibration-free
base.
! If the pump, which is going to be stored is equipped with a safety valve: Prior to storage
loosen the lock nut and turn the spring load set screw completely CLOCKWISE, using a
proper spanner, until the spring load is completely released!
8.3. Disposal
If the pump is to be disposed of, take care of the following items:
Clean the rotor case internally, it may still contain residual product.
Drain the oil from the gearbox.
Dispose of the pump using a company specialized in metal scrapping.

Table of Contents