POWER ELECTRONICS
SD700FR SERIES
91
PARAMETERS
FACTORY SETTINGS
SETTING 1
SETTING 2
11 T R3 OFF=0.0s
R3 DEACTIV DELAY
0.0s
___________________
___________________
12 INVERT R3=N
N
___________________
___________________
13 CRAspdOF=+5.0%
CRANE BRKoff SPD
+5.0%
___________________
___________________
G8: Outputs S8.2: Analogue Outputs
1 ANLG OUT 1=01
01
___________________
___________________
2 FORMT 1=4-20 mA
mA
___________________
___________________
3 MIN1 RNG=0%
MIN RANG ANAOUT1
+0%
___________________
___________________
4 MAX1 RNG=+100%
MAX RANG ANAOUT1
+100%
___________________
___________________
5 FILTER 1=OFF
FILTER ANAOUTPU1
OFF
___________________
___________________
6 ANLG OUT 2=02
02
___________________
___________________
7 FORMT 2=4-20 mA
4-20mA
___________________
___________________
8 MIN2 RNG=0%
MIN RANG ANAOUT2
+0%
___________________
___________________
9 MAX2 RNG=+100%
MAX RANG ANAOUT2
+100%
___________________
___________________
10 FILTER 2=OFF
FILTER ANAOUTPU2
OFF
___________________
___________________
G9: Comparators S9.1: Comparator 1
1 COMP 1 SEL=00
00
___________________
___________________
2 COMP 1 TYPE=0
0
___________________
___________________
3 SP C1 ON=+100[%]
C1 ACTIVAT LEVEL
+100[%]
___________________
___________________
4 LIM 2 C1=+100[%]
C1 WINDOW LIMIT2
+100[%]
___________________
___________________
5 LIM 1 C1=+0[%]
C1 WINDOW LIMIT1
+0[%]
___________________
___________________
6 T C1 ON=0.0s
C1 ACTIVAT DELAY
0.0s
___________________
___________________
7 SP C1 OF=0[%]]
C1 DEACTIV LEVEL
+0[%]
___________________
___________________
8 T C1 OF=0.0s
C1 DEACTIV DELAY
0.0s
___________________
___________________
9 SEL FUNT C1=00
00
___________________
___________________
G9: Comparators S9.2: Comparator 2
1 COMP 2 SEL=00
00
___________________
___________________
2 COMP 2 TYPE=0
0
___________________
___________________
3 SP C2 ON=+100[%]
C2 ACTIVAT LEVEL
+100[%]
___________________
___________________
4 LIM 2 C2=+100[%]
C2 WINDOW LIMIT2
+100[%]
___________________
___________________
5 LIM 1 C2=+0[%]
C2 WINDOW LIMIT1
+0[%]
___________________
___________________
6 T C2 ON=0.0s
C2 ACTIVAT DELAY
0.0s
___________________
___________________
7 SP C2 OF=0[%]
C2 DEACTIV LEVEL
+0[%]
___________________
___________________
8 T C2 OF=0.0s
C2 DEACTIV DELAY
0.0s
___________________
___________________
9 SEL FUNT C2=00
00
___________________
___________________

Table of Contents