3. Safety instructions
Premier Tech 11 / 64 Solido SMART
DOKK5110E 15.04.2020
3. Safety instructions
For the operation of the small wastewater treatment plant installation
Caution:
Electrical components are to be connected, started up, and opened only by
authorised specialist personnel. The power cord must be protected with a 30 mA
residual-current circuit breaker.
Caution:
The small wastewater treatment plant should be installed by qualified personnel
only. Make sure that the technical components can be accessed without any
danger. Any deviations from the installation instructions provided are the
responsibility of the specialist company and must be agreed upon with the
manufacturer. Never enter the system unless the power has been switched off
and the applicable accident prevention regulations are being observed (oxygen
deficiency).
Caution:
The connection of the small wastewater treatment plant to the mains supply must
be performed only by a specialist electrical company.
30 mA residual-current circuit breaker provided
Check the correct operation of the mains connection (protective earth
conductor intact?)
Operation
Caution:
Never disconnect the mains plug during regular plant operation.
The bacteria in the small wastewater treatment plant must have a regular supply
of oxygen.
For this reason, do not interrupt the power supply to the treatment plant, even
during longer periods of absence (such as holidays).