6. Inspection, maintenance and desludging
Premier Tech 27 / 64 Solido SMART
DOKK5110E 15.04.2020
6.4 Take sample of activated sludge from reactor chamber
measure current water level in reactor (HR)
aerate reactor per manual mode for 2min
evaluate mixing and size of bubbles
take 250 ml sample of mixed activated slugde and fill into 1000 ml cylinder
fill up with 750 ml of clearwater from sample pot (using the small sample
taking device) to reach “1+3 dilution”
allow settlement for 30min
multiply resulting sludge level by factor 4 to get SSV30 in ml/l
take picture and save it as part of maintenance report
Measure sludge volume in all chambers/tanks.
Contrary to regular SBR-plants the Solido SMART system is working with
comparatively high sludge volume values.
Why dilute 1+3?
Example after 30min
sedimentation:
The result of 600ml/l is
much closer to the real
conditions in the tank.
Undiluted
SSV30= 930ml/l
Dilution „1+3“:
SSV30= 150ml/l x 4 = 600 ml/l