EasyManua.ls Logo

PREMIER TECH Solido SMART - Page 29

PREMIER TECH Solido SMART
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6. Inspection, maintenance and desludging
Premier Tech 29 / 64 Solido SMART
DOKK5110E 15.04.2020
Table of max.regular water level at full hydraulic load HRmax:
Plant type
PE
HRmax
Height tank bottom to edge
of manhole as refernce for
on-site measurement
[m]
EBL-26
5 PE
0,92 m
1,57
EBL-30
5 PE
1,12 m
1,96
EBL-45
8 PE
1,35 m
2,24
EBL-52
10 PE
1,54 m
2,21
EBL-76
15 PE
1,68 m
2,28
EBL-99
20 PE
1,81 m
2,28
EBL-76X2
30 PE
1,71 m
2,28
EBL-99X2
40 PE
1,81 m
2,28
EBL-99X3
50 PE
1,85 m
2,28
EM2-35
5 PE
1,28 m
1,65
EM2-45
8 PE
1,23 m
1,65
EM2-60
10 PE
1,46 m
1,92
Usually the growth of SSV90 norm decreases slightly over time:
0
100
200
300
400
500
600
700
800
0 50 100 150 200 250 300 350 400
SV90norm in ml/l
time period (days)
chron.trend SSV90
norm
at SMART (idealised)