9. Operational failures and resolving them
Premier Tech 52 / 64 Solido SMART
DOKK5110E 15.04.2020
Measures to be taken when an alarm occurs
Recommendations for the operator:
• Press the middle button once
The warning signal is permanently stopped
The red LED light continues to flash
Error message remains in the bottom line of the basic screen
Alarm is not triggered again
Only for specialist companies:
• Press the middle button again
Alarm is deactivated (until it is entered in the fault memory)
Error message at the bottom of the basic screen
The plant is now “re-armed”.
An alarm is issued again at the next available opportunity if the cause of the error
has not been eliminated
An interruption in the power supply will also deactivate an alarm.
The S40 control unit has a ring memory for 40 error and event messages (e.g. also
NETWORK ON/OFF). You will find it in the menu “system”: display errors
A short interruption of power supply (<1 min) will be registered as mains break.
An interruption >1 min will be registered as mains OFF and mains ON (with time and date).
Exception: Overfill alarm cannot be deactivated.
The alarm stops once the sensor moves down again.
Note:
For more information, see chapter 8 “S40 control unit and available settings”