28 PRODIGIT
Description Condition/Value Description Condition/Value
MODE CC C.F. 2
LOAD OFF FREQ FREQ = 60.0Hz
LEVEL A BANK = 0
SENSE OFF SYNC = OFF
PRES OFF CC LEVEL A 00.00A
WATT OFF CC LEVEL B 00.00A
LIMIT V
LIMIT
= 400.0V LIN LEVEL A 00.00A
A
LIMIT
= 120.00A LIN LEVEL B 00.00A
W
LIMIT
=12000 W CR LEVEL A 8888Ω
VA
LIMIT
= 12000 W
CR LEVEL B 8888Ω
Table 3-9 32615A initial Condition Setting
Description Condition/Value Description Condition/Value
MODE CC C.F. 2
LOAD OFF FREQ FREQ = 60.0Hz
LEVEL A BANK = 0
SENSE OFF SYNC = OFF
PRES OFF CC LEVEL A 00.00A
WATT OFF CC LEVEL B 00.00A
LIMIT V
LIMIT
= 400.0V LIN LEVEL A 00.00A
A
LIMIT
= 140.00A LIN LEVEL B 00.00A
W
LIMIT
= 14000 W
CR LEVEL A 7616Ω
VA
LIMIT
= 14000 W
CR LEVEL B 7616Ω
Table 3-10 32616A initial Condition Setting