EasyManua.ls Logo

Prodigit 3260A Series - Table 4-2 Gpib;Rs-232 C Query Command Summary

Default Icon
69 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PRODIGIT 3260A Series Operation Manual 39
Query Command
Function Command Syntax ECHO
QUERY AUTO FREQUENCY
DETECT ON/OFF
AFREQ{|NL} 1ON, 0OFF
QUERY SYNC SYNC{|NL} 1ON, 0OFF
QUERY SENS ON/OFF SENS{|NL} 1ON, 0OFF
QUERY WATT ON/OFF WATT{|NL} 1ON, 0OFF
QUERY BANK BANK{|NL} 0 10
QUERY WAVE WAVE{|NL} 0 4
QUERY FREQUENCY FREQ{|NL} ###.####
QUERY VOLTAGE LOW LIMIT
VL{|NL} ###.####
QUERY VOLTAGE HIGH LIMIT
VH{|NL} ###.####
QUERY CURRENT LOW LIMIT
IL{|NL} ###.####
QUERY CURRENT HIGH LIMIT
IH{|NL} ###.####
QUERY WATT LOW LIMIT WL{|NL} ###.####
QUERY WATT HIGH LIMIT WH{|NL} ###.####
QUERY VA LOW LIMIT VAL{|NL} ###.####
QUERY VA HIGH LIMIT VAH{|NL} ###.####
QUER POWER METER (W) MEASPOW{|NL} ###.####
QUERY VA METER MEASVA{|NL} ###.####
QUERY No Good INDICATER NG{|NL} 0OFF, 1ON
QUERY CURRENT CURR {LOW|HIGH|A|B} {
|NL}
###.####
QUERY RESISTANCE RES{LOW|HIGH|A|B}{|NL}
###.####
QUERY LINEAR CURRENT LIN{A|B}{|NL} ###.####
QUERY LOAD ON/OFF LOAD{|NL} 1ON, 0OFF
QUERY LEVEL A/B LEV{|NL} 0LOW/A, 1HIGH/B
QUERY PRESET ON/OFF PRES{|NL} 1ON, 0OFF
QUERY MODE CC/CR/LIN MODE{|NL} 0CC, 1CR, 2LIN
QUERY NAME NAME{|NL} 326X SERIES
QUERY PROTECT STATE PROT{|NL} 0 F(hex)
QUERY CURRENT METER MEASCURR{|NL} ±###.####
QUERY VOLTAGE METER MEASVOLT{|NL} ±##.####
Table 4-2 GPIB/RS-232C QUERY COMMAND SUMMARY
REMARK :
1. CURRENT ENGINEERING UNITA
2. VOLTAGE ENGINEERING UNITV
3. RESISTANCE ENGINEERING UNIT