Housing parts: Polyphenylene ether (PPE with fibreglass)
17.5
Electrical data
Parameter M70 M85
Nominal power**, approx. 25 W 30 W
Current I eff 0.25 ... 0.10 A 0.30 ... 0.12 A
Switch on peak current (for 3 ...5 ms) 20 A 20 A
Fuse* 2.5 slow blow 2.5 slow blow
** With relay closed: The nominal power rises by 1 watt.
* Fuses must have VDE, UL and CSA certification. e.g. type 19195
manufactured by Wickmann in compliance with IEC Publ. 127 - 2/3
17.6
Temperatures
Data Value Unit
Storage and transport temperature: -20 ... +50 °C
Ambient temperature in operation
(power end/drive and control):
-10 ... +45 °C
Medium temperature: -10 °C ... see
following
table
Material version Long term Temporary *
PP 50 °C 100 °C
NP 45 °C 60 °C
PV 50 °C 120 °C
SS 50 °C 120 °C
TT 50 °C 120 °C
* Max. temp., for 15 min. at max. 2 bar, depending on the ambient temperature
Drive unit
Design: 100 ... 230 V ±10%, 50/60
Hz, gamma/ X GMXa
Pump, complete
Liquid ends
Technical data
119
DosingPump.ir

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent gamma/ X GMXa and is the answer not in the manual?

ProMinent gamma/ X GMXa Specifications

General IconGeneral
BrandProMinent
Modelgamma/ X GMXa
CategoryWater Pump
LanguageEnglish

Related product manuals