20 Diagrams for Setting the Capacity
0
1,0
2,0
3,0
4,0
5,0
6,0
7,0
8,0
9,0
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
90
80
70
100
50
40
30
20
10
60
0
2,0
4,0
6,0
8,0
10,0
12,0
14,0
16,0
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
90
80
70
100
50
40
30
20
10
60
0
0,5
1
1,5
2
2,5
3
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
90
80
70
100
50
40
30
20
10
60
200 1/min
180 1/min
160 1/min
140 1/min
120 1/min
100 1/min
80 1/min
60 1/min
40 1/min
20 1/min
C [l/h] f [%]
s [%]
GMXa 0708
C [l/h] f [%]
s [%]
GMXa 0414
C [l/h] f [%]
s [%]
GMXa 1602
200 1/min
180 1/min
160 1/min
140 1/min
120 1/min
100 1/min
80 1/min
60 1/min
40 1/min
20 1/min
200 1/min
180 1/min
160 1/min
140 1/min
120 1/min
100 1/min
80 1/min
60 1/min
40 1/min
20 1/min
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
90
80
70
100
50
40
30
20
10
60
C [l/h] f [%]
s [%]
GMXa 1604
200 1/min
180 1/min
160 1/min
140 1/min
120 1/min
100 1/min
80 1/min
60 1/min
40 1/min
20 1/min
0
0,2
0,4
0,6
0,8
1
1,2
1 1,5 2 3 4
p [bar]
k
AA
BB
0
0,5
1
1,5
1 2 4 6 8 11 13 16
p [bar]
k
AA
BB
0
0,5
1
1,5
1 2 4 6 8 11 13 16
p [bar]
k
AA
BB
0
0,2
0,4
0,6
0,8
1
1,2
1 2 3,5 4 6 7
p [bar]
k
AA
BB
Fig. 72: A) Capacity C at maximum back pressure depending on the stroke length s for different
stroke rates f. - B) Corresponding correction factors k dependent on back pressure p - at 70 % strokelength,
"Automatic"-"Off" and "Compensation"-"Off".