0
10
20
30
40
50
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
90
80
70
100
50
40
30
20
10
60
C [l/h] f [%]
s [%]
GMXa 0245
200 1/min
180 1/min
160 1/min
140 1/min
120 1/min
100 1/min
80 1/min
60 1/min
40 1/min
20 1/min
0
5
10
15
20
25
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
90
80
70
100
50
40
30
20
10
60
C [l/h] f [%]
s [%]
GMXa 0424
200 1/min
180 1/min
160 1/min
140 1/min
120 1/min
100 1/min
80 1/min
60 1/min
40 1/min
20 1/min
0,8
0,85
0,9
0,95
1
1,05
0,5 1 1,5 2
p [bar]
k
A
BB
0
0,2
0,4
0,6
0,8
1
1,2
1 1,5 2 3 4
p [bar]
k
AA
BB
Fig. 74: A) Capacity C at maximum back pressure depending on the stroke length s for different
stroke rates f. - B) Corresponding correction factors k dependent on back pressure p - at 70 % strokelength,
"Automatic"-"Off" and "Compensation"-"Off".
Diagrams for Setting the Capacity
158