P_MAZ_0001_SW
2
1
Fig. 15: Standard installation
1
Main line
2
Storage tank
Symbol
Explanation
Symbol
Explanation
Metering pump
Foot valve with filter meshes
Injection valve
Level switch
Multifunctional valve
Manometer
Legend for hydraulic diagram
Installation, hydraulic
38
DosingPump.ir
37
39
Table of Contents
Default Chapter
3
Table of Contents
3
1 About this Pump
6
2 Identity Code
7
3 Safety Chapter
10
Labels
10
Intended Use
11
Safety Information
11
Information in the Event of an Emergency
14
Personnel Qualification
14
4 Storage, Transport and Unpacking
16
5 Overview of Equipment and Control Elements
17
Overview of Equipment
17
Control Elements
18
Key Functions
22
6 Functional Description
24
Liquid End
24
Drive Unit
24
Capacity
26
Self-Bleeding
26
Operating Modes
26
Functions
27
Relays (Options)
28
LED Displays
28
Hierarchy of Operating Modes, Functions and Fault Statuses
29
7 Assembly
30
8 Installation, Hydraulic
32
Installing Hose Lines
33
Installation with Metering Pumps Without Degassing
33
Installation with Metering Pumps with Degassing
35
Installation with Metering Pumps with Self-Degassing (SEK Type)
36
Basic Installation Notes
37
9 Installation, Electrical
39
Supply Voltage Connector - Power Supply
40
HMI Operating Unit
41
Description of the Terminals
41
External Control" Terminal
41
Level Switch" Terminal
43
Metering Monitor" Terminal
43
Diaphragm Rupture Indicator" Terminal
44
Relays
45
10 Basic Set-Up Principles
49
Basic Principles for Setting up the Control
49
Checking Adjustable Variables
51
Changing to Setting Mode
51
11 Set up / 'Menu
52
Information
52
Settings
52
Operating Mode
53
Automatic
58
Stroke Length
58
Metering
59
Concentration
63
Calibrate
70
System
71
Inputs/Outputs
73
Bleeding
79
Priming Time
80
Set Time
81
Date
81
Timer
81
Activation / Deactivation
82
Setting the Timer
82
Clear All
88
Examples
88
Timer Information
90
Typical Pitfalls Timer Functional Faults
90
Brief Explanation of Selected Functions
91
Service
92
Access Protection
92
Password
93
Clear Counters
93
Error Log Book
93
Diaphragm Replacement
94
Display
94
Factory Settings
94
Diaphragm Part Number: XXXXXXX
94
Spare Parts Kit Part Number: XXXXXXX
94
Language
95
12 Operation
96
Manual Operation
96
13 Maintenance
98
14 Repair
100
Replacing the Diaphragm
101
Replacing the Vptfe Diaphragm
103
Cleaning the Diaphragm Rupture Indicator
103
Cleaning Valves
104
15 Troubleshooting
105
Faults Without a Fault Message
105
Faults with Error Message
106
Fault Messages on the LCD Screen
106
Warning Messages on the LCD Screen
108
All Other Faults
109
Log Book
109
Fault Messages in the Log Book
109
Warning Messages in the Log Book
110
Event Messages in the Log Book
111
Log Book Entry - Detailed View
111
16 Decommissioning and Disposal
113
17 Technical Data
115
Performance Data
115
Performance Data with Vptfe Diaphragm
116
Accuracy
117
Standard Liquid End
117
Self-Bleeding Liquid End
117
Viscosity
118
Material Specifications
118
Electrical Data
119
Temperatures
119
Climate
120
Altitude of Site
120
Degree of Protection and Safety Requirements
120
Degree of Protection
120
Safety Requirements
120
Degree of Pollution
120
Compatibility
120
Shipping Weight
121
Sound Pressure Level
121
18 Exploded Drawings and Ordering Information
122
Exploded Drawings
122
Ordering Information
146
19 Dimensional Drawings
147
20 Diagrams for Setting the Capacity
156
21 Declaration of Conformity for Machinery
159
22 Declaration of Conformity
160
23 Approvals
161
24 Operating/Set-Up Overview of the Gamma/ X
162
25 Gamma/ X Operating Menu, Overall
164
26 Continuous Displays and Secondary Displays
170
27 Installation Instructions: Retrofitting Relays
172
28 Index
174
5
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the ProMinent gamma/ X GMXa and is the answer not in the manual?
Ask a question
ProMinent gamma/ X GMXa Specifications
General
Brand
ProMinent
Model
gamma/ X GMXa
Category
Water Pump
Language
English
Related product manuals
ProMinent gamma/l
81 pages
ProMinent gamma XL
160 pages
ProMinent delta
47 pages
ProMinent Sigma/3
124 pages
ProMinent Beta BT5a
54 pages
ProMinent Sigma Series
8 pages
ProMinent concept plus
13 pages
ProMinent EXtronic EXBb
72 pages
ProMinent DULCO flex Control
120 pages
ProMinent CONCEPT PLUS Series
60 pages
ProMinent EXtronic EXBb Series
56 pages
ProMinent Sigma/ 2 Control S2Cb
100 pages