P_G_0054_SW
Fig. 39: The leakage hole
Interval Maintenance work Personnel
Annually*
n Check the diaphragm for damage - refer to "Repair".
Technical personnel
* with normal loading (approx. 30% of continuous operation).
With heavy-duty loading (e.g. continuous operation): Shorter inter‐
vals.
Check the metering diaphragm more frequently or use a dia‐
phragm rupture indicator with feed chemicals that put particular
pressure on the diaphragm, e.g. those containing abrasive addi‐
tives.
Interval Maintenance work
Quarterly* In addition:
n Check that the bypass line is fixed firmly to the liquid end.
n Check that the vent valve is tight.
n Check the pressure and bypass line for kinks.
n Check that the vent valve is operating correctly.
* with normal loading (approx. 30% of continuous operation).
With heavy-duty loading (e.g. continuous operation): Shorter inter‐
vals.
Data Value Unit
Tightening torque for screws: 4.5 ... 5.0 Nm
Liquid ends with vent valve:
Tightening torque
Maintenance
99
DosingPump.ir

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent gamma/ X GMXa and is the answer not in the manual?

ProMinent gamma/ X GMXa Specifications

General IconGeneral
BrandProMinent
Modelgamma/ X GMXa
CategoryWater Pump
LanguageEnglish

Related product manuals