6 Post-InstallaonInstrucons
Before rst me startup of the feeder, check:
Table2. Post-InstallaonChecklist
Item
No
Check Completed?
1. Is there any residual debris (plasc shavings, screws, and so on) inside the soluon tank?
2. Has the booster pump been fully primed?
3. Are all electrical lines secure and not a tripping hazard?
4. Are all exposed electrical and instrument lines protected and do they meet eld condions?
5. Does the booster pump motor plug line up to the correct voltage supply?
6. Is the control box cover closed and screws securely ghtened?
7. Are all ngs and unions ghtened to prevent leaks?
8. Are ow direconal arrows pointed in the correct direcon of ow on the venturi, solenoid valves, and
check valves?
9. Is grid basket placed in HCE bowl correctly so that it cannot spin around?
10. Is the control box feeder cable connected to the feeder cable and is the locking ring turned clockwise to
seal the two connectors together?
6.1 System Startup
Note: Before starng up the equipment, ensure that the Post-Installaon checklist has been
completed.
6.1.1 FeederPreparaon
Aer compleng the post-installaon checklist:
1. Put on the appropriate PPE: long sleeved clothing, rubber gloves, apron, dust mask, and safety glasses.
Danger: Use suitable personal protecve equipment (PPE) at all mes to avoid physical
contact with calcium hypochlorite liquid or vapor. Failure to do so may result in death
or serious injury. Please refer to the Safety Data Sheet for addional informaon and
precauons regarding the proper handling of calcium hypochlorite.
2. Open the hopper lid.
3. If not already installed, place grid basket in to the hopper. Conrm that only one grid basket is installed in the hopper and placed in the
correct orientaon where the basket spout is on the bowl outlet. (Basket should not be able to rotate when placed correctly).
4. Use a scoop to add approximately 3 inches of Pulsar® Plus Briquees to the basket.
5. Close the hopper lid.