EasyManua.ls Logo

Pyronix Castle EURO 46 Series

Pyronix Castle EURO 46 Series
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EURO 46, 162 & 280 Programming Manual
Page: 48
Type Active Restore
0034 Lights When exit or entry timer starts
20 seconds after set/unset
procedure completed
0035
Follow Input
Refer to page: 16
When input triggers Dependent upon programming
0036 Shunt Fault Refer to Shunt Inputs (Page: 16)
0037 Restore 1 At code entry to set After 3 seconds
0038 Restore 2
At code entry to set When unset
Re-triggers whenever an additional area is set
0039 PIR Latch 1 When set (and in Walk Test) At alarm, or when unset
0040 PIR Latch 2 This is the inverse polarity to PIR Latch 1
0041 Mains Good Output showing the mains is healthy
0042 Detr Indn Enable
This output activates during walk test and also when a code is entered to
view indications – staying activated for the time for which the indications
are viewed.
0043 Follow Test New output for alternative bell test by activating SAB
0044 Off During Test New output for alternative bell test by activating SAB
0048 Detr Walk Test
This output is active during walk test, and will only deactivate when all
detectors have been tested.
0049 Detector Masked
If any detector goes into ‘mask’
condition the output will trigger
When masking fault clears.
0050 Follow 24 Hour
If any input programmed as “Day
alarm” activates
When input restored
0051 Line Fault
When Line Fault signalled by
communicator
When fault clears
0052 Mains Fail
After pre-set time without mains
power
On restoration of mains
0053 Battery Faults
When battery disconnected or load
fail detected
At next valid code entry
0054 Low Volts At fault When fault clears
0055
Global Fault 1
(Faults: Modem, Battery,
Fuse, Line, Mains)
Activates if fault occurs only when
system is armed
When all faults cleared
0056
Global Fault 2
(Faults: as above)
Activates if fault occurs at any time When all faults cleared
0058 Guard Code Used When ‘guard’ code accepted After 60 seconds
0059 Engineer Access When entering Engineer Mode Leaving Engineer Mode
0060 Initialise Digi At power up Live for 45 seconds only
0063 Test ATE Test signalling through PSTN When test completed
0064
Test ATS
For use with ATE
complying with BSIA Form
175 to initiate test call to
ARC by each available
path.
Test signalling through PSTN
Activates when a test call is sent.
When test completed
0065 Zone Activity Fail
If an input with NAT timer active
does not trigger in the defined
period
Next valid code entry
0066 ATE not used Makes the ATE pin 5V or 0V depending if ATE outputs are inverted
0070-0079 Fob Output 01-10
Can be used to triggers outputs via the keyfob. For example if an output is
programmed as type 0071 (Fob Output 02) and is wired to a garage door.
And if a user has a keyfob programmed with button 2 as Latched or
Keyswitch Output (with Output 2 selected), then when the button is
pressed the garage door will open.

Related product manuals