EURO 46, 162 & 280 Programming Manual
Page: 49
Type Active Restore
0070-0079 Fob Output 01-10
A repeating block of output types should be noted:
0202 Hold Up A As 0002 for Area A / Level set A events only
0203 Intruder A As 0003 for Area A / Level set A events only
0204 Final Set A As 0004 for Area A / Level set A events only
0206 Confirmed A As 0006 for Area A / Level set A events only
0207 Tamper A As 0007 for Area A / Level set A events only
0208 Duress A As 0008 for Area A / Level set A events only
0209 HU Device A As 0009 for Area A / Level set A events only
0210 Fire Reset A As 0010 for Area A / Level set A events only
0213 Secure Intruder A As 0013 for Area A / Level set A events only
0214 Siren A As 0014 for Area A / Level set A events only
0216 Strobe A As 0016 for Area A / Level set A events only
0217 Omit At Rearm A As 0017 for Area A / Level set A events only
0218 Unconfirmed A As 0018 for Area A / Level set A events only
0219 Can Set A As 0019 for Area A / Level set A events only
0220 Exit Starts A As 0020 for Area A / Level set A events only
Then this pattern repeats for each other area, so that:
0221-0240 Area / Level set B 0361-0380 Area / Level set 4
0241-0260 Area / Level set C 0381-0400 Area / Level set 5
0261-0280 Area / Level set D 0401-0420 Area / Level set 6
0281-0300 Area / Level set 0 0421-0440 Area / Level set 7
0301-0320 Area / Level set 1 0441-0460 Area / Level set 8
0321-0340 Area / Level set 2 0461-0480 Area / Level set 9
0341-0360 Area / Level set 3
1xxx Follow input xxx When input is activated When input clears
i.e. add 1000 to the input number to select output required
Area Sounder At output 2 of the TMZ (fixed as loudspeaker)