Page: 21
5.10 Change Codes?
5.10.1 Five Digit PINs?
Set this option to [1] (Yes): to allow the use of 5 digit and 6 digit codes (This will disable codes below
5 digits in length). Set this to [0] (No): if you would prefer to use codes below 5 digits in length.
5.10.2 Change Duress/Guard Codes?
This function changes the Engineer code, the Master Manager code and adds/changes/deletes any
Duress or Guard codes.
Default Codes: Master Manager: 2222. Engineer: 1111
NOTE: User codes, fobs and keyfobs can only be changed in The Master Manager menu, however
users can change their own codes (if a user code has been set up). Please see the user manual for
more information.
5.10.3 Change Duress Codes -> User Type:
[2] Duress Code: If the Control Panel is unset using a 'Duress' code, a silent 'Duress' or
'Hold Up' signal is sent.
NOTE: ACPO policy prevents use of Duress codes for police call purposes.
[3] Guard: A 'Guard code' can be used to unset the Control Panel only after an alarm has
been activated for a minimum time of three minutes. The code will set a system and an
output type is available to signal when this code is used (00058 Guard Code).
[4] Dial Out: If a dial out code is programmed and entered when the Control Panel is unset,
the PC number 1 that is programmed (see 'SET UP DOWNLOADING' on page: 34) will be
dialled.
5.10.4 Change Master Manager Code
The Master Manager code can be 4, 5 or 6 digits long, or can be assigned to a tag. It may also
have the following functions:
User Areas: (01ABCD) The areas to which the code applies.
User Set Options: [0] Unset/Set. [1] Unset Only. [2] Set Only. [3] None (menu access only).
Flexi Set: If enabled the default area the device is assigned to will set. If disabled the default
area will be shown on the display and from here other areas can be selected.
Wards/Access: This will only be displayed if an Entry Control or Access Control reader is
installed on the system. If the address of the Entry Control or Access Control device is entered
here, then the code will be assigned to that reader only.
User Name: Enter a name for the user or group that use this code.
5.10.5 Change Engineer Code
The Engineer code can be 4, 5 or 6 digits long.
Change Codes Programming
1. Press or to scroll to 'CHANGE CODES'. Press .
2. 'Change Duress Codes' will be displayed. Press to add
any Duress, Guard or Dial out codes (as described previously)
or press .
3. 'Change Master Manager Code' will be displayed. Press to
change the Master Manager code or press .
4. 'Change Engineer Code' will be displayed. Press to
change the Engineer code or press to return to the
Engineer menu.
CHANGE CODES?
Change Duress
Codes?
Change Master
Manager Code?
Change Engineer
Code?

Other manuals for Pyronix EURO 46 APP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix EURO 46 APP and is the answer not in the manual?

Pyronix EURO 46 APP Specifications

General IconGeneral
BrandPyronix
ModelEURO 46 APP
CategoryControl Panel
LanguageEnglish

Related product manuals