Page: 48
SMS Control Enable?
SMS Set No [0]
SMS Unset No [0]
SMS Status No [0]
SMS Output No [0]
SMS Number Edit No [0]
SMS Start UDL No [0]
Advanced Communications?
Program PCs [1]
Modem Tel No
Signal Alarms No [0]
Signal Faults No [0]
Signal Set/Unset No [0]
Signal Access C(Control). No [0]
ALARM RESPONSE? Silent 1
st
Alarm Never [0]
Disable Confirm On Entry No [0]
Area A, B, C, D, 0, 1 Starts at Digi [3]
Area A, B, C, D, 0, 1 Stops at Confirm [4]
Fire Starts at, Stops at Digi [3]
Gas Starts at, Stops at Digi [3]
HU Starts at Digi [3]
Hu Stops at Confirm [4]
Day alarm starts, stops Sirens Only [2]
Start at, Stop at Digi [3]
If area set [------]
SET UP DOWNLOADING? Download by None [0]
Security Level Normal [0]
Always Poll Cloud No [0]
Roving Dial No [0]
13. Event Types (SIA and Contact ID codes)
Event
SIA
code
CID
code
Event
Type
Number
Default 1
(ARC)
Full
Reporting
Default 2
(ARC)
No
Arm/Disarm
Default 3
(ARC)
No
Arm/Disarm
and Alarm
Restorals
Default
(SMS)
SET
Auto Set CA 3403 1
on
Forced Set CF 3401 1
Set CL 3401 1
UNSET
Unset OP 1401 2
on
Auto Unset OA 1403 2
(Special Set/Unset) SET/UNSET WITH CODES 15 to 25
Special Unset OP 1401 3
on
Special Set CL 3401 3
SUBAREA / SHUNT SET/UNSET
Sub-Area Set CG 3402 4
on
Shunt Closed 1402 4
Sub-Area Unset OG 1402 5
Shunt Opened 3402 5
INTRUDER ALARM
Intruder Alarm BA 1130 7 all all all once