5.11 Volume Control?
The Volume Control function applies to both the main sounder, the on-board keypad or any additional
keypads.
5.11.1 Area A,B,C,D,0,1 Entry Tone Volume
0=Completely Silent, 1=Silent, but beeps when the system is set. 2-5 keypad 6&7 = Main Sounder
5.11.2 Area A,B,C,D,0,1 Exit Tone Volume
0=Completely Silent, 1=Silent, but beeps when the system is set. 2-5 keypad 6&7 = Main Sounder
5.11.3 Area A,B,C,D,0,1 APP Exit Tone Volume
0=Completely Silent, 1=Silent, but beeps when the system is set. 2-5 keypad 6&7 = Main Sounder
5.11.4 Alarm Volume
0=Completely Silent, 1=Silent, but beeps when the system is set. 2-5 keypad 6&7 = Main Sounder
5.11.5 Fire Alarm Volume
0=Completely Silent, 1=Silent, but beeps when the system is set. 2-5 keypad 6&7 = Main Sounder
5.11.6 Tamper Alarm Volume
0=Completely Silent, 1=Silent, but beeps when the system is set. 2-5 keypad 6&7 = Main Sounder
5.11.7 Day Alarm Volume
0=Completely Silent, 1=Silent, but beeps when the system is set. 2-5 keypad 6&7 = Main Sounder
5.11.8 Chime Volume
0=Completely Silent, 1=Silent, but beeps when the system is set. 2-5 keypad 6&7 = Main Sounder
5.11.9 Code Stops Sound
If this function is enabled, then once an alarm has been generated (even if the code is not
programmed for that area) the alarm will be silenced, and a ‘Misoperation (Abort) signal’ will be sent.
The area will remain set until a code or tag is presented that is assigned to that area
5.11.10 Entry/Exit Keypads Only
If this function is disabled, any entry and exit tones will be heard through the main sounder.
If enabled, the entry and exit tones will only be heard through the keypad speaker.
5.11.11 Alert Kps Only
If this function is enabled, any 'Alert' tones will be heard on the keypad only and not the main
sounder. If disabled, the alert tones will heard through both.
5.11.12 Silent Technical Alert
If this function is enabled then any technical alerts will be silenced, such as: line fault, ARC
call fail.

Other manuals for Pyronix EURO 46 APP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix EURO 46 APP and is the answer not in the manual?

Pyronix EURO 46 APP Specifications

General IconGeneral
BrandPyronix
ModelEURO 46 APP
CategoryControl Panel
LanguageEnglish

Related product manuals