EasyManua.ls Logo

Quadra-Fire CASTILE - Pellet Venting Charts

Quadra-Fire CASTILE
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
R
October 27, 2011
Page25
Castile & Santa Fe CE Insert
7069-101B
F. Pellet Venting Charts
FireRisk.
• Only LISTED venting components may be
used.
• NOOTHERventcomponentsmaybeused.
Substituteordamagedventcomponentsmay
impairsafeoperation.
WARNING
Themaximumhorizontalventingallowedwithnoverticalvent-
ing attached is 219mm including one 90° elbow or two 45°
elbows. Thisis our recommended horizontalventing instal-
lation. Addition of any horizontal venting beyond 1219mm
Hearth&HomeTechnologiesstrongrecommendsaminimum
of1524mmofadditionalvertical vent.Horizontalsectionsof
ventpipeshouldhavea6.35mmriseperfoot.
Hearth & Home Technologies recommends any installation
requiring more than two 90° elbows, or more than 4.5m of
ventingtouse102mmvent.
NOTICE: Theseareguidelinesforsuccessfulventingofyourpelletappliance.Themoreverticalriseyoucanobtaininyoursystem,
thebetteritwillperform.Horizontalventrunscanaccumulateashandwillneedtobecleanedmoreoften.Trytokeepthemasshort
aspossible.
45°elbowisequivalentto30.48cmofstraightpipe
90°elbowisequivalentto91.44cmofstraightpipe
Miniumum Vertical Vent for Three Elbows
0.00
1.00
2.00
3.00
4.00
5.00
6.00
7.00
0 1 2 3 4
Length of Horizontal Sections (M)
Minimum Vertical Rise
(M)
Miniumum Vertical Vent for Two Elbows
0.00
1.00
2.00
3.00
4.00
5.00
6.00
0 1 2 3 4 5 6
Length of Horizontal Sections (M)
Minimum Vertical Rise (M)
Figure 27.1
Miniumum Vertical Vent for One Elbow
0.00
1.00
2.00
3.00
4.00
5.00
6.00
0 1 2 3 4 5 6
Horizontal Run (M)
Minimum Vertical Rise
(M)
Figure 27.2
Figure 27.3
ONE 90º ELBOW
Total
Horizontal
Minimum
Vertical
Vent
Diameter
4 0 3
5 5 3
6 6 3
7 7 3
8 8 4
9 9 4
10 10 4
11 11 4
12 12 4
13 13 4
14 14 4
15 15 4
16 16 4
17 17 4
18 18 4
19 19 4
TWO 90º ELBOWS
Total Minimum Vent
Horizontal Vertical Diameter
2 5 3
3 6 3
4 7 3
5 8 3
6 9 3
7 10 4
8 11 4
9 12 4
10 13 4
11 14 4
12 15 4
13 16 4
14 17 4
15 18 4
THREE 90º ELBOWS
Total Minimum Vent
Horizontal Vertical Diameter
2 11 4
3 12 4
4 13 4
5 14 4
6 15 4
7 16 4
8 17 4
9 18 4
10 19 4
11 20 4

Table of Contents