Page6
October 27, 2011
R
Castile & Santa Fe CE Insert
7069-101B
A. Appliance Certication
B. Glass Specications
D. Specications
Thisapplianceisequippedwith5mmceramicglass.Replace
glass only with 5mm ceramic glass. Please contact your
dealerforreplacementglass.
C. Electrical Rating
230VAC,50Hz,Start2.80Amps,Run0.80Amps
*Thermaloutputwill vary, dependingon the type of fuel
you use in your appliance. Consult your Quadra-Fire
dealerforbestresults.
NOTICE: Hearth&HomeTechnologies,manufacturer
ofthisappliance,reservestherighttoalteritsprod-
ucts,theirspecicationsand/orpricewithoutnotice.
WARNING! Risk of Fire! Hearth&HomeTechnologiesdis-
claimsanyresponsibilityfor,andthewarrantyandagency
listingwillbevoidedbythefollowingactions.
DO NOT:
• Installoroperatedamagedappliance
• Modifyappliance
• Useasanincineratororanyotherdifferentwayfrom
whichitwasconceived
• Install other than as instructed by Hearth & Home
Technologies
• Operate the appliance without fully assembling all
components
• Overre
• Install any component not approved by Hearth &
HomeTechnologies
• InstallpartsorcomponentsnotListedorapproved.
Improper installation, adjustment, alteration, service or
maintenancecancauseinjuryorpropertydamage.
Forassistanceoradditionalinformation,consultaqualied
installer,serviceagencyoryourdealer.
1
Listing and Code Approvals
Model CastileorSantaFePelletInsertAppliance
Type ResidentialSpaceheatingappliancered
bywoodpellets
Standard EN14785:2006
Hearth&HomeTechnologies
1445NorthHighway
Colville,WA99114
UnitedStates
2011
Quadra-Fire is a registered trademark of Hearth &
Home Technologies
NOTE: Some generator or battery back-up systems may
not be compatable with the micro-processor electron-
ics on this appliance. Please consult the power supply
manufacturer for compatable systems.
Distance to Adjacent
Combustion Materials:
StandofftoSide:410mm
StandofftoHeader:305mm
CO Concentration at 13%
O
2
(mg/m
3
):
Max:0.003%
Min:0.030%
Flue Gas Temperature: 161°C
*Thermal Output:
Max:6.3kW
Min:3.0kW
Energy Efciency: Max:75.1%
Min:75.0%
Heating Capacity: 220m
2
to350m
2
Hopper Capacity: 18kg
Fuels: WoodPellets,lessthan
38mminlength,6mmto
8mmindiameter
Shipping Weight: 109kg,add18kgwhenthe
hopperisfull