BMC CONFIGURATION GROUP
3-53
Procedure:
1. In KVM encryption, check or uncheck the option Enable.
2. Choose the Keyboard Language from the list of supported keyboard languages.
3. Enter a value in the Retry Count field to set the number of attempts for retrying the
redirection session.
4. Enter a value in the Retry Interval field to assign time interval for each attempt.
5. Select the Local Monitor OFF check box to enable Local Monitor ON/OFF com-
mand during runtime.
6. Select the Automatically OFF Local Monitor, When JViewer Launches check box
to automatically lock the local monitor during JViewer launch.
7. In Virtual media Attach mode, select Auto Attach or Attach from the drop-down
list as required.
8. Click Save to save the current changes.
9. Click Reset to reset the modified changes.
SMTP
Simple Mail Transfer Protocol (SMTP) is an Internet standard for electronic mail (e-mail)
transmission across Internet Protocol (IP) networks.
Using MegaRAC GUI, you can configure the SMTP settings of the device.
Automatically OFF Local
Monitor, When JViewer
Launches
Enable/disable Automatically OFF Local Monitor, When JViewer Launches.
Save
To save the current changes.
Note:
It will automatically close the existing remote redirection either KVM or Vir-
tual media sessions, if any.
Reset To reset the modified changes.
Table 20: Remote Session Settings Page (Continued)
ITEM DESCRIPTION

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the QUANTA QuantaGrid S31A-1U and is the answer not in the manual?

QUANTA QuantaGrid S31A-1U Specifications

General IconGeneral
BrandQUANTA
ModelQuantaGrid S31A-1U
CategoryServer
LanguageEnglish

Related product manuals