BMC USER PRIVILEGE
3-97
change BMC configuration, just to trigger Identify LED used to display where
Server is. So it is expected behavior. After checked other Operator privilege
command by IPMI 2.0 Specification, Chassis Control command (Power On/
Off) is also allowed. But in our code base, we raise Chassis Control com-
mand to be Administrator to protect system. So, in Server Power Control
page, only Administrator can control server power.
Login BMC through SSH
ID: sysadmin, Password: superuser
Web Account can’t login SSH
SMASH
If supported SMASH then to login SSH will go to SMASH.
If NOT Support SMASH then to login SSH will go to BMC console.
Table 40: User Privilege
WEB GUI PRIVILEGE LIST
PRIVILEGE ASSOCIATION BETWEEN IPMI AND WEB GUI
A
DMINISTRATOR OPERATOR
USER/
CALLBACK
OEM
login BMC from Web GUI O O X O
configure BMC from Web GUI O X X X
configure users from Web GUI O X X X
clear logs from Web GUI O XXX
execute server power control from Web GUI O X X X
virtual KVM redirection O X X X
virtual media O X X X
View Users O O X X
View DNS O O X X
View Network O O X X
View PEF O O X X