Communication Protocol TCP/IP Communications Setup Command Set
CubiScan 25 Service Manual 81
Set Gateway Address
This command is used to set the network gateway address on the CubiScan 25. It can be the
address of a network server or router and is expressed in “dot” notation. Consult your network
administrator to obtain the network gateway address.
Pos Len Description Type Range ASCII
Command Format
1 1 Start of Text Control (STX) 02h
2 1 Set Command Alpha (@) 40h
31
Gateway Address
Command
Alpha (G) 47h
4
7-15
or n
IP Address Alpha
(0.0.0.0) to
(255.255.255.255
)
4+n 1 End of Text Control (ETX) 03h
5+n 1 Carriage Return Control (CR) 0Dh
6+n 1 Line Feed Control (LF) 0Ah
Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Set Command Alpha (@) 40h
31
Gateway Address
Command
Alpha (G) 47h
41Acknowledge Alpha(A) 41h
51End of Text Control(ETX) 03h
6 1 Carriage Return Control (CR) 0Dh
7 1 Line Feed Control (LF) 0Ah
Negative Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Set Command Alpha (@) 40h
31
Gateway Address
Command
Alpha (G) 47h
4 1 Neg. Acknowledge Alpha (N) 4Eh
51End of Text Control(ETX) 03h
6 1 Carriage Return Control (CR) 0Dh
7 1 Line Feed Control (LF) 0Ah