Communication Protocol TCP/IP Communications Setup Command Set
CubiScan 25 Service Manual 79
TCP/IP Communications Setup Command Set
This section describes the commands recognized by the CubiScan 25 to set up the CubiScan 25
for communications with a network using the TCP/IP protocol.
You can use the Qbit, QbitTCP software to configure the CubiScan 25 for TCP/IP
communications. Contact Quantronix for information.
Configuration of the CubiScan 25 for TCP/IP communication is performed through the RS-232-C
serial communications port using the following commands.
TCP/IP Command Set Summary
The table below shows the Command Set Summary for TCP/IP.
(A) - Command Character
(B) - Command Hex Value(s)
21Zero Command Alpha (Z) 5Ah
31Neg. Acknowledge Alpha (N) 4Eh
41End of Text Control(ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
61Line Feed Control(LF) 0Ah
TCP Configuration Name (A) (B) Page
“Read Gateway Address” ~G 40h+47h 80
“Set Gateway Address” @G 7Eh+47h 81
“Read IP Address” ~I 40h+49h 82
“Set Subnet Address” @I 7Eh+49h 82
“Set Subnet Address” ~M 40h+4Dh 83
“Set MAC Address” @M 7Eh+4Dh 84
“Read Port” ~P 40h+50h 85
“Set Port” @P 7Eh+50h 86
“Read Subnet Address” ~N 40h+4Eh 87
“Set Subnet Address” @N 7Eh+4Eh 88
Pos Len Description Type Range ASCII