Set value is used in one direction from Base to Remote (Remote to Base direction
is configured in Remote unit in its Radio protocol settings). If the Remote station
is behind Repeater, set value is used for both radio hops: Base station - Repeater
and Repeater - Remote.
Retries
Set value is used in one direction from Base to Remote (Remote to Base direction
is configured in Remote unit in its Radio protocol settings). If the Remote station
is behind Repeater, set value is used for both radio hops: Base station - Repeater
and Repeater - Remote.
CTS Retries
Default = 3 [0=Off, 15=Max]
Based on sophisticated internal algorithm, Base station sends a CTS (Clear To
Send) packet which allows Remote station to transmit. If the Remote station is
connected directly to the Base station (not behind Repeater), and the Base station
doesn't receive a frame from the Remote station, the Base station repeats permis-
sion to transmit.
Connection
List box: Direct, Direct & Repeater, Behind Repeater
Default = Direct
Type of radio connection between Remote and the Base station defines the position
of the respective unit in the radio network topology:
Direct
Remote station having direct radio communication with the Base station.
Direct & Repeater
Remote station having direct radio communication with the Base station and
acting as a Repeater.
Behind Repeater
Remote station communicating with the Base station over a Repeater station.
Max. one Repeater can be used between any Remote and the Base station.
More than one Remote stations can be behind one Repeater.
Repeater Protocol address
If Remote station is 'Behind Repeater' type, Protocol address of the Repeater must
be assigned.
Note
You may add a note to each address with your comments up to 16 characters
(UTF8 is supported) for your convenience. (E.g. " Remote unit #1 " etc.). Following
characters are not allowed:
" (Double quote)
` (Grave accent)
\ (Backslash)
$ (Dollar symbol)
; (Semicolon)
Active
You may tick/un-tick each line in order to make it active/not active
RipEX Radio modem & Router – © RACOM s.r.o.128
Advanced Configuration