Initial Configuration
48 Document ID: RDWR-ALOS-V2815_IG0203
Initial Screen for Alteon Application Switch 5412
The following is example text of the initial screen for Alteon Application Switch 5412.
Virtual Application Delivery Infrastructure (VADI™)
Platforms Installation and Configuration
Alteon VA is part of Radware's Virtual Application Delivery Infrastructure (VADI™) architecture,
where ADC and virtualization services are integrated into an Application Delivery Virtualization
Infrastructure. This section describes the installation and configuration instructions for VADI
platforms and includes the following topics:
ADC Form Factors, page 48
Alteon VA for VMware Installation and Configuration, page 49.
Alteon VA for KVM Installation and Configuration, page 51
.
Alteon VA for Open Xen Installation and Configuration, page 58
.
Initial Deployment of Alteon VA, page 59
.
Obtaining and Installing a Permanent License for Alteon VA, page 61
.
For specifications of the Alteon VA platform, see The Alteon VA Platform, page 89
.
ADC Form Factors
Hypervisors or virtual machine managers (VMM), allow multiple operating systems, termed guests,
to run concurrently on a host computer. They support three different ADC form factors or footprints:
Dedicated ADC — The traditional Alteon hardware ADC.
vADC — A virtualized instance of the Alteon operating system (AlteonOS).
Alteon VA — A software-based ADC supporting AlteonOS functionality and running on a
virtualization infrastructure. Alteon VA is supported by the following hypervisor types:
System Information at 11:39:49 Mon May 10, 2010
Time zone: No timezone configured (GMT offset -8:00)
Memory profile is Default
Alteon Application Switch 5412
Switch is up 0 days, 0 hours, 0 minutes and 17 seconds.
Last boot: 11:39:32 Mon Feb 1, 2010 (reset from console)
Last apply: 11:21:07 Mon Feb 1, 2010
Last save: 11:35:29 Mon Feb 1, 2010
MAC Address : 00:03:b2:ff:ff:c0
IP (If 10) Address : 50.0.0.2
Hardware MainBoard No|Rev : MEKX-MB-DBS-BP | B.07
Hardware DB No|Rev : MEKX-E4SFP | B.02
Hardware Serial Number : 21111119
Note - When the measured temperature inside the switch EXCEEDs
the anomaly threshold at 54 degree Celsius or the critical
temperature at 73 degree Celsius different syslog messages
will be generated.
Software Version
28.1.5.0 (FLASH image1), active configuration.

Table of Contents

Other manuals for Radware Alteon

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Radware Alteon and is the answer not in the manual?

Radware Alteon Specifications

General IconGeneral
ModelAlteon
ManufacturerRadware
LayerLayer 4-7
TypeApplication Delivery Controller (ADC)
FeaturesLoad balancing, SSL offloading, application acceleration, DDoS protection
Form FactorVirtual Appliance