Chapter 5 Diagnostics and Troubleshooting WinLink 1000 Installation and Operation Manual
Q: After reselection Channel Reselection link is not established for long
time. How can I recover the link?
A: Click "cancel", then open the site configuration dialog and set the
unit to install mode. The remote side of the link shall enter install
mode on the installation channel.
Services
Q: What is the actual Ethernet data rate and maximum throughput?
A: The Max net throughput of the WinLink 1000 is Full Duplex 18
Mbps.
Note
The WinLink 1000 is a symmetrical system
Q: Does WinLink 1000 withhold any MAC Addresses?
A: The WinLink 1000 is a layer 2 Bridge (VLAN transparent). The built in
switch contains a MAC Address table up to 2047.
Q: What are the BER values expected in the WinLink 1000 link?
A: 1E-10 (according to BER sensitivity threshold)
Antennas and Cables
Q: Can I use any category 5e cable in order to connect the IDU and
ODU?
A: The cable should be suitable for outdoor use, and shielded
Category 5e.