RAEGuard 2 PID User’s Guide
37
Unit ID
When using Modbus communication, you can give each RAEGuard 2
PID on a network a unique Unit ID that helps identify it.
1. Press [+] repeatedly to select a desired number. Numbers
increase from 0 to 9. Once 9 is reached, pressing [+] again
“wraps” around back to 0.
2. Press [-] to advance to the next digit.
Repeat this process until both digits of the new value are
entered.
3. Press [MODE] to save the 20mA analog output value.
LCD Contrast
The display’s contrast can be increased or decreased from its default
setting. You may never need to change the default setting, but
sometimes you can optimize the display to suit extreme temperature
and ambient brightness/darkness conditions.
1. Press [+] to step through the contrast levels. The range is 1 to
99. Once 99 is reached, pressing [+] again "wraps" around
back to 10.
2. When you have completed your selection, press [MODE].
3. Press [+] to save your selection, and exit LCD Contrast.
Note: If you want to make further changes, press [MODE] to
return to the adjustment screen. Press [-] to exit without
saving the changes.
LCD Backlight
The backlight glows whenever you press a button with the magnetic
key. In addition, you can set the backlight to be either always on or
only on when an event (alarm) occurs.
1. Press [-] to place the cursor on the setting you want.
2. Press [+] to make the selection.
3. Press [MODE] to save your selection, exit the LCD Backlight
submenu and return to the Monitor Setup menu.

Table of Contents

Related product manuals