R&S ESU Instrument Functions
Receiver Mode
4.36 Operating Manual 1302.6163.12 - 03
THRESHOLD
ON | OFF
The THRESHOLD ON | OFF softkey activates or deactivates the THRESHOLD
SCAN measurement function. This function will also be activated on opening the
submenu with the THRESHOLD SCAN softkey from the RECEIVER main menu.
Remote command: FME:THR OFF
EDIT PEAK
LIST
The EDIT PEAK LIST softkey calls the EDIT PEAK LIST submenu used for editing
the peak list.
The function of the softkeys are described under the FINAL MEAS / EDIT PEAK
LIST submenu.
Further functions relating to the peak list are described in section “Measurement of a
Peak List” on page 4.158.
NO OF
PEAKS
With the NO OF PEAKS softkey, you can enter the number of final measurement
peaks to be stored. Numbers between 1 and 500 can be entered. If the selected
number is attained, no further final measurements will be performed.
Remote command: :CALC:PEAK:SUBR 1...500
NB/BB
DISCR
With the NB/BB DISCR softkey, you can enter the decision threshold to be used by
the analyzer to discriminate between broadband and narrowband interference. Val-
ues between 0 dB and 200 dB can be entered.
Remote command: :FME:NBBB ON | OFF
:FME:NBBB:LEVel 0..200dB
SORT BY FREQUENCY
SORT BY DELTALIMIT
ASCII FILE EXPORT
DECIM SEP
PAGE UP
PAGE DOWN
NO OF PEAKS
NB/BB DISCR
MARGIN
FINAL MEAS TIME
AUTOMATIC FINAL
INTER ACTIVE
RUN SCAN
Side menu
ESH2-Z5 | ESH3-Z5 |
ENV 4200 | ENV 216 |
OFF
PRESCAN PHASES |
FINAL PHASES
!
RUN SCAN