EasyManua.ls Logo

Rational VarioCooking Center 112 - Connected Loads

Rational VarioCooking Center 112
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Connected loads
3 NAC 400 V
112 112 with
vitro
211 211 with
vitro
311 311 with
vitro
Power (kW)* 17 19 28 31 45 47
Current consumption (A) 23 34 47 47 70 70
Fuse (A) 25 40 50 50 80 80
Cross section
recommended (mm²)
2,5 6 10 10 16 16
3 NAC 400 V Dynamic
112 112 with
vitro
211 211 with
vitro
311 311 with
vitro
Power (kW)* 13 15 22 24 35 37
Current consumption (A) 19 29 37 37 56 57
Fuse (A) 20 32 40 40 63 63
Cross section
recommended (mm²)
2,5 4 6 6 10 10
3 NAC 415 V
112 112 with
vitro
211 211 with
vitro
311 311 with
vitro
Power (kW)* 18 20 30 32 47 50
Current consumption (A) 25 35 49 49 74 74
Fuse (A) 25 40 50 50 80 80
Cross section
recommended (mm²)
2,5 6 10 10 16 16
3 NAC 415 V Dynamic
112 112 with
vitro
211 211 with
vitro
311 311 with
vitro
Power (kW)* 14 17 23 26 37 40
Current consumption (A) 19 30 39 39 58 59
Fuse (A) 20 32 40 40 63 63
Cross section
recommended (mm²)
2,5 4 6 6 10 10
Caution:
As written on page 14, the unit has to be connected through a 30 mA circuit breaker.
- 17 -
v08

Related product manuals