Connected loads
3 NAC 400 V
112 112 with
vitro
211 211 with
vitro
311 311 with
vitro
Power (kW)* 17 19 28 31 45 47
Current consumption (A) 23 34 47 47 70 70
Fuse (A) 25 40 50 50 80 80
Cross section
recommended (mm²)
2,5 6 10 10 16 16
3 NAC 400 V Dynamic
112 112 with
vitro
211 211 with
vitro
311 311 with
vitro
Power (kW)* 13 15 22 24 35 37
Current consumption (A) 19 29 37 37 56 57
Fuse (A) 20 32 40 40 63 63
Cross section
recommended (mm²)
2,5 4 6 6 10 10
3 NAC 415 V
112 112 with
vitro
211 211 with
vitro
311 311 with
vitro
Power (kW)* 18 20 30 32 47 50
Current consumption (A) 25 35 49 49 74 74
Fuse (A) 25 40 50 50 80 80
Cross section
recommended (mm²)
2,5 6 10 10 16 16
3 NAC 415 V Dynamic
112 112 with
vitro
211 211 with
vitro
311 311 with
vitro
Power (kW)* 14 17 23 26 37 40
Current consumption (A) 19 30 39 39 58 59
Fuse (A) 20 32 40 40 63 63
Cross section
recommended (mm²)
2,5 4 6 6 10 10
Caution:
As written on page 14, the unit has to be connected through a 30 mA circuit breaker.