For other voltages please contact the manufacturer
* Doesn't include power consumption from the embedded socket.
** Not available!
3 AC 400 V
112 112 with
vitro
211 211 with
vitro
311 311 with
vitro
Power (kW)* 13 ** 26 ** 42 **
Current consumption (A) 19 ** 41 ** 61 **
Fuse (A) 20 ** 50 ** 63 **
Cross section
recommended (mm²)
2,5 ** 10 ** 10 **
3 AC 440 V
112 112 with
vitro
211 211 with
vitro
311 311 with
vitro
Power (kW)* 16 ** 22 ** 35 **
Current consumption (A) 19 ** 37 ** 56 **
Fuse (A) 20 ** 40 ** 63 **
Cross section
recommended (mm²)
2,5 ** 6 ** 10 **
3 AC 200 V
112 112 with
vitro
211 211 with
vitro
311 311 with
vitro
Power (kW)* 17 19 28 30 45 47
Current consumption (A) 49 58 98 98 146 146
Fuse (A) 50 63 100 100 160 160
Cross section
recommended (mm²)
10 10 25 25 50 50
3 AC 220 V
112 112 with
vitro
211 211 with
vitro
311 311 with
vitro
Power (kW)* 15 17 25 26 40 42
Current consumption (A) 39 49 78 78 117 117
Fuse (A) 40 50 80 80 125 125
Cross section
recommended (mm²)
6 10 16 16 35 35
Connected loads
- 18 -