Standard AccuFlow™ Installation
FIGURE 12. Dual Cooler AccuFlow System Alternate Installation (D/N 016-0171-508)
Checking for System Leaks
Once the AccuFlow™ has been installed on the implement, check the system for leaks by charging the system
with compressed air and applying soapy water to all plumbing joints and hoses. Thoroughly examine plumbing
connections for bubbles indicating any kind of leak. Fix any leaks before charging the AccuFlow™ system with
anhydrous ammonia.