Selectingaspeedresolution
FromtheUserCalibrationMenu:
1.PresstheSpeedbuttonuntiltheSpeed
Resolutionpageisdisplayed(2pressesfrom
theUserCalibrationentrypage).
D12428-2
Spe ed
2.UsetheTimerorResetbuttonstoselectthe
requiredresolutionforspeedreadings.
Theresolutionsavailableare0.01(default)and
0.1.
Note:ToexittheUserCalibrationpagesatany
time,pressandholdtheSpeedandTripbuttons
atthesametimeforapproximately2seconds.
Selectingtheunitofmeasureforlogreadings
FromtheUserCalibrationMenu:
1.PresstheSpeedbuttonuntiltheLogUnits
pageisdisplayed(3pressesfromtheUser
Calibrationentrypage).
D12429-2
Spe ed
2.UsetheTimerandResetbuttonstoselectthe
requiredunitofmeasurementforlogreadings.
SM(default)StatuteMiles
NMNauticalMiles
KMKilometers
Note:ToexittheUserCalibrationpagesatany
time,pressandholdtheSpeedandTripbuttons
atthesametimeforapproximately2seconds.
1pointspeedcalibration
Theinstrumentdisplay’sspeedreadingscanbe
calibratedusinga1pointcalibrationprocess,inmost
situationthisisallthatwillberequiredtocalibrate
ourspeedreadings.
Prerequisites:
ForbestresultsSOGdatashouldbeavailable,or
analternativemethodofestimatingvesselspeed
mustbeused(e.g.vesselspeedcanbeestimated
usingNauticalMeasuredMileMarkersorsimilar
landmarksofaknowndistanceapart).
Youwillneedtobeunderway,withsufcientspace
tomaneuverunhindered.
Inordertoachieveaccurateresults,water
conditionsmustbecalmwithzerotideandzero
current.
FromtheUserCalibrationMenu:
1.Steeryourvesselonasteadycourseata
constanttypicalspeed.
2.PresstheSpeedbuttonuntil1oftheCurrent
Speedpagesisdisplayed(4pressesfromthe
UserCalibrationentrypage).
IfSOGdataisavailableoverSeaT alk
ng
then
theSOGpageisdisplayed,ifSOGdataisnot
availablethentheCalibrationFactorpageis
displayed.
D12430-2
Spe ed
Spe ed
SOG
SOG
3.IftheSOGpageisdisplayedandthewater
conditionsareacceptable,pressandholdthe
Resetbuttonforapproximately3secondsto
acceptSOGasthecurrentlogspeed.
D12432-2
10
15
20
25
30
35
40
45
50
55
60
5
3
Re s e t
4.Alternatively,withtheCalibrationFactorpage
displayedusetheTimerandResetbuttonsto
adjustthecalibrationfactoruntilthedisplayed
speedmatchesyourestimatedspeed.
Thedefaultcalibrationfactoris1.00.The
calibrationfactorcanbesetfrom0.25to2.50.
5.IfSOGisavailableyoucanswitchbetweenthe
CalibrationFactorandSOGpagesbypressing
theTimerandResetbuttonsatthesametime.
D12431-2
+
Time r
Re s e t
Note:ToexittheUserCalibrationpagesatany
time,pressandholdtheSpeedandTripbuttons
atthesametimeforapproximately2seconds.
Nauticalmeasuredmilemarkers
WhenneitherSOGdataoranyotherreliablemeans
ofestimatingSpeedThroughtheWater(STW)is
available,NauticalMeasuredMileMarkerscan
beusedtohelpcalibrateLogSpeed.Nautical
measuredmilemarkersareidentiedbytwopairsof
postsortowers.Thedistancebetweeneachpairof
markersis1nauticalmile.
Eachmarkerinapairisseparatedbydistanceand
elevationfromitspartner.Thefrontmarkeriscloser
tothewaterandshorterthanthemarkerbehindit.
i50Speed