4.
1Generalcablingguidance
Cabletypesandlength
Itisimportanttousecablesoftheappropriatetypeandlength
Unlessotherwisestateduseonlystandardcablesofthecorrecttype,suppliedbyRaymarine.
Ensurethatanynon-Raymarinecablesareofthecorrectqualityandgauge.Forexample,longer
powercablerunsmayrequirelargerwiregaugestominimizevoltagedropalongtherun.
Routingcables
Cablesmustberoutedcorrectly,tomaximizeperformanceandprolongcablelife.
DoNOTbendcablesexcessively.Whereverpossible,ensureaminimumbenddiameterof200
mm(8in)/minimumbendradiusof100mm(4in).
Protectallcablesfromphysicaldamageande xposuretoheat.Usetrunkingorconduitwhere
possible.DoNOTruncablesthroughbilgesordoorways,orclosetomovingorhotobjects.
Securecablesinplaceusingtie-wrapsorlacingtwine.Coilanyextracableandtieitoutoftheway.
Whereacablepassesthroughanexposedbulkheadordeckhead,useasuitablewatertight
feed-through.
DoNOTruncablesneartoenginesorfluorescentlights.
Alwaysroutedatacablesasfarawayaspossiblefrom:
otherequipmentandcables,
highcurrentcarryingACandDCpowerlines,
antennas.
Strainrelief
Ensureadequatestrainreliefisprovided.Protectconnectorsfromstrainandensuretheywillnotpull
outunderextremeseaconditions.
Circuitisolation
AppropriatecircuitisolationisrequiredforinstallationsusingbothACandDCcurrent:
Alwaysuseisolatingtransformersoraseparatepower-invertertorunPC’s,processors,displays
andothersensitiveelectronicinstrumentsordevices.
AlwaysuseanisolatingtransformerwithWeatherFAXaudiocables.
Alwaysuseanisolatedpowersupplywhenusinga3rdpartyaudioamplifier.
AlwaysuseanRS232/NMEAconverterwithopticalisolationonthesignallines.
AlwaysmakesurethatPC’sorothersensitiveelectronicdeviceshaveadedicatedpowercircuit.
Cableshielding
Ensurethatallcablesareproperlyshieldedandthatthecableshieldingisundamaged.