EasyManua.ls Logo

Reboot RBC5000D - Troubleshooting - Arc Transfer and Cutting Issues; Pilot Arc Fails to Transfer to Work; Pilot Arc Turns Off During Cutting

Default Icon
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E-5
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
E-5
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Authorized Field Service Facility
for technical troubleshooting assistance before you proceed.
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
Pilot arc starts but will not transfer
when brought near work.
1.
Check work lead connection for
clean, secure connection.
2.
Plasma will only cut conductive
material. Do not attempt to cut
fiberglass, plastic, rubber, PVC or
any other non-conductive material.
3.
Make sure work piece is clean and
dry. Remove any scale, rust or
dross.
4.
Possible faulty Inverter board.
5.
Check all connections to Control
board.
If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Authorized Field
Service Facility.
Pilot arc initiates but turns off before
transferring to work. Cutting arc
appears to turn off while cutting.
1.
Input voltage is below 220V/110V.
2.
Air pressure is set too high.
Lower air pressure by turning regula-
tor knob.

Related product manuals