TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
E-6
STATUS BOARD INDICATORS
SYMPTOM
CHECK
When trigger is pulled Green power LED
is steady with no air flow.
1. Make sure there is at least 60 psi connected to the gas connec-
tion at the back of the machine.
2. Turn the output knob to the purge zone and set the regulator to
the correct pressure. The pressure may increase when air stops
flowing but this is normal. Do not reset the pressure while the air
is OFF.
3. Possible faulty Pressure Switch.
4. Possible faulty Inverter board.
The Thermal LED is lit.
1.
The machine's thermostat has tripped due to exceeded duty
cycle limits. Do NOT turn the power off. Allow the machine to
cool for 15 - 30 minutes and the thermostat will reset itself.
2.
The machine's air louvers or fans are obstructed such that air
cannot flow to properly cool the machine. Remove any foreign
material that may block air flow. Blow the machine out with a
clean, dry air stream.
3.
The input voltage is not within ±10% of rated values.
4.
Possible faulty Inverter board.
When the trigger is pulled the Green LED is
lit, air flows and no pilot arc occurs.
1. Check that swirl ring is properly installed.
Note: Swirl ring can only go in one way.
When the trigger is pulled no air flows,
Green LED is lit, no pilot arc. Then LED
goes out.
1. Check that the pressure gauge shows pressure.
Air supply may not be connected or properly installed.