Page 20 of 55 12/2006 Rev. B Manual DFA 127 Full Power
Commissioning
M+S
Turn off the operator
M+S
Mount arms Approx. 6° initial tension
M+S
Check that the retarding effort while
closing without mains supply is cor-
rect
M+S
Turn on the operator
With Master/Slave-Installations
turn on the Slave first.
M
Set the locking mechanism and
door type
M
Switch to manual mode With operation switch BDI
M+S
Connect the sensor-bars SIO, SIS
(if available)
These sensors should work prop-
erly, because they are adjusted
during the calibration run.
M MF 3. light pulse
Start the calibration run
S MF 3. light pulse
Start the calibration run
M+S
Connect the sensors and actuators
to AKI/AKA if present
M+S
Final settings of the operators
For Master / Slave- installations, also refer to chapter 16
The door must not be obstructed in any way during the calibration run.
In case of uncontrolled door motion, immediately disconnect the mains
power supply by turning off the main switch or unplugging the mains
power plug.