Page 26 of 55 12/2006 Rev. B Manual DFA 127 Full Power
Operating instructions
Manual operation / HAND
The door can be opened and closed by hand. The manual operation mode can be
adjusted individually with 6 parameters. The description of the parameters is found
with the parameters.
Open continuously/ OPEN
The door is opened and stays open.
Locked
The locking is activated in the Locked operation mode.
Table of signals (X marks a release reaction)
Closed Opening Open Closing
AKI x x x
AKA x x x
SSK x x x x
SIO x x x
SIS x x
TIPP
OFF
This operation mode can be used only in the USA. The operator is switched to
manual operation (without configurations). An SSK opening is possible, but only
under surveillance because some monitoring functions are disabled. Functions like
parameter settings, Flash-update, continue to work.
Table to signals (X marks a release reaction)
Closed
Opening Open closing
AKI
AKA
SSK x x x x
SIO
SIS
TIPP
BODYG x x
RAILB
x x
RESET
After pushing the button for approx. 5 seconds, this status message on the
display will read:
No
Reset Operator?
Yes
Push on the button again to reset the operator.