U1500E Gas Fireplace | 29
installation
Vertical Venting with Three (3) 90
o
Elbows
One 90
o
elbow = Two 45
o
elbows.
Option V H + H1 V + V1
With these options,
max. total pipe length
is 30 feet with min. of
10 feet total vertical
and max. 8 feet total
horizontal.
Please note min. 1
foot between 90
o
elbows is required.
A) 0' Min. 2' Max. 2' Min.
B) 1' Min. 2' Max 3' Min.
C) 2' Min. 3' Max 4' Min.
D) 3' Min. 4' Max 6' Min.
E) 4' Min. 5' Max 7' Min.
F) 5' Min. 6' Max 8' Min.
G) 6' Min. 7' Max 9' Min.
H) 7' Min. 8' Max 10' Min.
Restrictor Set 0 - 5" Factory Setting

Table of Contents