Mechanised Interlocks
48
11 Mechanised interlocks
Mechanised interlocks with metallic separation are only available factory
fitted.
11.1 RTC units with 7-pin interface (only for RTC 100
and RTC 150)
Input: “Cutting on/off” closing contact, always required.
Output: “Current-flow” message contactless for “Cutting arc on” Can be used for
external further processing, e.g. as precondition to starting control or
similar.
Article number: 756 1152
Standard: 5m cable
11.2 RTC units with 17-pin interface (only for RTC 100
and RTC 150)
Inputs: Current set point for the range l
min
to l
max
linear 0-10V or connection of
potentiometer (< = 10 kOhm)
“Cutting on/off” closing contact or “On” if U>18V
Outputs: “Current-flow” message contactless for “Cutting arc on” Can be used
for external further processing, e.g. as precondition to starting
control or similar.
Group alarm “RTC unit fault” by closing contact. Can be used for
external further processing, e.g. as error message on control or
similar.
- Actual value of cutting voltage 0-5V linear for 0-500V.Can be used
for external further processing, e.g. for arc voltage height control or
similar.
Article number: 756 1010
Standard: 5m cable