NC4 non-contact tool setting system: NC4 basics
Guidelines for best practice
The NC4 unit is a precision device and must be handled with care.
Ensure that all mountings are secure.
Keep electrical contacts clean.
Mount the NC4 unit in a position that limits the risk of it being subjected to impact when operating the
machine.
Mount the NC4 unit in a position where it will not be affected by a build-up of swarf. Do not allow
excessive waste material to build up on or around the NC4 unit.
Cables, piping and conduit should be suitably secured to avoid damage and loads being transferred to
the NC4 unit.
Optimum performance is achieved by continuously supplying air and power to the NC4 unit.
The NC4 unit is protected by a continuous stream of clean air. Approximately once a month, inspect
the optics for contamination. The service interval may be extended or reduced depending on
experience.
The NC4 barrier air supply must conform to BS ISO 8573-1 air quality of Class 1.4.2 and be moisture-
free.