Output Mode
SM Appendix 5-5 C274
Appendix:
SP Mode
Tables
No. Name Note
2-45 Clamper Motor: to open
2-46 Pressure Plate Motor: to limit
2-47 Pressure Plate Motor: to home
position
2-48 Main Motor: 30rpm
2-49 Main Motor: 60rpm
2-50 Main Motor: 90rpm
2-51 Paper Feed Motor: 30rpm
No. Name Note
2-52 Paper Feed Motor: 60rpm
2-53 Paper Feed Motor: 90rpm
Press and hold the master making key
to start the test. Release the key to stop
the test.
SP2-41: Thermal Head Signal Output (VHD Signal)
Applies thermal head voltage.
Power is applied by pressing the # key. To protect the thermal head, the voltage supply is
automatically stopped after 30 seconds. It is also stopped by pressing the clear/stop key.
( Replacement and Adjustment – Master Feed - Thermal Head Voltage Adjustment)