Image Adjustment
SM 4-7 C274
Replacement
and
Adjustment
DIPSW101-1 DIPSW101-2 DIPSW101-3 DIPSW101-4 Difference Difference
ON ON ON ON +7 pulse +3.563 mm
OFF ON ON ON +6 pulse +3.054 mm
ON OFF ON ON +5 pulse +2.545 mm
OFF OFF ON ON +4 pulse +2.036 mm
ON ON OFF ON +3 pulse +1.527 mm
OFF ON OFF ON +2 pulse +1.018 mm
ON OFF OFF ON +1 pulse +0.509 mm
OFF OFF OFF ON 0 0
OFF OFF OFF OFF 0 0
ON ON ON OFF -7 pulse -3.563 mm
OFF ON ON OFF -6 pulse -3.054 mm
ON OFF ON OFF -5 pulse -2.545 mm
OFF OFF ON OFF -4 pulse -2.036 mm
ON ON OFF OFF -3 pulse -1.527 mm
OFF ON OFF OFF -2 pulse -1.018 mm
ON OFF OFF OFF -1 pulse -0.509 mm
1 pulse = 0.509 mm
4.3.5 DIPSW101 NO.5 TO 8 – MASTER WRITING POSITION
ADJUSTMENT
Purpose: To match the printing side-to-side on the print paper with that on the original.
Adjustment standard: ±1.0 mm
The master writing position moves as shown below.