1.SC Codes
105
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
START signal being output.
Motor connector disconnected
Abnormal increase in Fuser Belt Smoothing Roller torque (overload due to
the bearing lock, etc.)
Motor driver defective
-
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC551-
00
A
Thermistor disconnection: Pressure Roller NC Sensor
Pressure Roller NC Sensor detected 0 degree or lower 105 seconds
consecutively after the heater was turned on
Thermistor disconnection
Connecter contact failure
Replace the Pressure Roller NC Sensor.
Reconnect the connector.
Replace the Fuser Unit.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC552-
01
A
Reload Failure: Pressure Roller NC Sensor
Pressure Roller NC Sensor detected a temperature below 45 degrees 105
seconds consecutively after the heater was turned on.
Thermistor deformed or floating
Input voltage out of specification
Check for fusing lamp disconnection
Replace the Pressure Roller NC Sensor
Replace the Pressure Roller Thermostat
Replace the Pressure Roller Fusing Lamp
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC552-
02
A
Reload Failure: Pressure Roller NC Sensor
Reload permission temperature is not reached 260 seconds after motor control is
started.
Lamp disconnection
After the operation of overheat prevention mechanism
Check for fusing lamp disconnection
Replace the Pressure Roller NC Sensor
Replace the Pressure Roller Thermostat

Table of Contents