1.SC Codes
112
Error Name/Error Condition/Major Cause/Solution
Thermopile disconnected or defective
Thermistor disconnected or defective
Reconnect or replace the Fusing Thermistor (Roller Shaft)
Replace the fuser unit.
Error Name/Error Condition/Major Cause/Solution
Sensor 8: Fusing Thermistor (Roller Shaft) disconnected 2
When temperatures lower than 50°C are detected continuously for 1055 seconds
or more, SC occurs. (Excluded time: 400 seconds are excluded.)
The monitoring cycle is 100 ms.
Thermopile disconnected or defective
Thermistor disconnected or defective
Reconnect or replace the Fusing Thermistor (Roller Shaft)
Replace the fuser unit.
Error Name/Error Condition/Major Cause/Solution
Temperature Decrease Detection: Heating Roller Thermopile
Disconnection during paper feed
The thermopile detected -10 degrees less than target temperature after correction
continuously for 150 seconds or longer during or after paper feeding
Removal time: 50 seconds (excludes removal time)
Replace the fusing lamp.
Replace the Heating Roller Thermopile.
Replace the Fuser Unit.
Error Name/Error Condition/Major Cause/Solution
Secondary Power Cord Not Connected
The main power cord is connected but the secondary power cord is not
connected.
The secondary power cord is not connected.
Circuit breaker is off.
Harness broken
AC drive/IOB defective.
Turn the machine off and plug in the secondary power cord again.
Check that the circuit breaker is on. If off, turn it on.
Replace the harness.
Replace the AC drive/IOB.