1.SC Codes
125
Error Name/Error Condition/Major Cause/Solution
Check if the SC occurs by turning the power OFF then ON. If the SC occurs again,
do the following steps. Check if the SC reoccurs by cycling the power after each
step.
1. Reconnect the ADF connector.
2. Update the firmware (engine and ADF).
3. Replace the ADF harness.
4. Replace the engine board.
5. Replace the IPU.
6. Replace the ADF control board.
Error Name/Error Condition/Major Cause/Solution
ADF communication error 3
The CIS initialization completion command is not received within the specified
period.
ADF defective
IPU board defective
Electrical noise on the line
Check if the SC occurs by turning the power OFF then ON. If the SC occurs again,
do the following steps. Check if the SC reoccurs by cycling the power after each
step.
1. Reconnect the ADF connector.
2. Replace the ADF harness.
3. Replace the ADF control board.
Error Name/Error Condition/Major Cause/Solution
Finisher/mail box communication error
Detected an error when connecting the communication line.
Received a communication error notification from the URAT.
Finisher Main Board defective.
BCU or IOB defective
Harness between finisher and main unit defective/disconnected/shorted
Check if the SC occurs by turning the power OFF then ON. If the SC occurs again,
do the following steps. Check if the SC reoccurs by cycling the power after each
step.
1. Reconnect he harness between the finisher and the main unit.
2. Replace the harness between the finisher and the main unit.