1.SC Codes
128
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
Replace the harness between IPU and PSU-5V1.
Replace the BCU.
Replace the IPU.
Replace the PSU-5V1
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC665-05
D
IOB does not start
The IOB_WAKE signal (Master or Slave) of the IOB and the PFB is not "WAKE".
IOB damaged
BCU damaged
Connector defective between BCU and IOB
BCU defective
Harness between BCU and IOB: Grounding fault
Replace the IOB.
Replace the BCU board.
Reconnect the BCU and IOB.
Replace the PFB
Replace the harness between BCU and IOB.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC665-
06
D
BCU Error
Occurs when the IOB_Wake signal (master or slave) is not on the Wake
side.
BCU damaged
BCU defective
1. Replace the BCU.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC669
BCU_EEPROM Communication Error
SC669-
01
D
BCU_EEPROM OPEN: ID error
SC669-
02
D
BCU_EEPROM OPEN: Channel error
SC669-
03
D
BCU_EEPROM OPEN: Device error
SC669-
D
BCU_EEPROM OPEN: Communication abort error

Table of Contents