1.SC Codes
150
Error Name/Error Condition/Major Cause/Solution
Check if the SC occurs (feed paper, open/close the doors, Input or Output check).
If the SC occurs again, do the following steps.Check if the SC reoccurs by cycling
the power after each step.
1. Check the harness connection.
2. Replace the encoder harness.
3. Replace the Transport Motor.
4. Remove torn paper from the paper path, remove foreign objects from the
drive area, and check for motor/motor bracket deformation.
Error Name/Error Condition/Major Cause/Solution
Scan Motor error (1-pass ADF)
Error signal detected while the motor is driven.
Connecter disconnected
Harness broken
Overload
Check if the SC occurs (feed paper, open/close the doors, Input or Output check).
If the SC occurs again, do the following steps.Check if the SC reoccurs by cycling
the power after each step.
1. Check the harness connection.
2. Replace the encoder harness.
3. Replace the Scan Motor.
4. Remove torn paper from the paper path, remove foreign objects from the
drive area, and check for motor/motor bracket deformation.
Error Name/Error Condition/Major Cause/Solution
Exit Motor error (1-pass ADF)
Error signal detected while the motor is driven.
Connecter disconnected
Harness broken
Overload
Check if the SC occurs (feed paper, open/close the doors, Input or Output check).
If the SC occurs again, do the following steps.Check if the SC reoccurs by cycling
the power after each step.