1.SC Codes
194
Error Name/Error Condition/Major Cause/Solution
Replace the slave control board.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Master-to-relay board communication error
IPU occupancy not obtained
IPU detected an error
Master control board defective.
Connector loose, broken, defective
Reconnect the connector.
Replace the relay board.
Replace the master control board.
Replace the harness.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Slave-to-cutter control board communication error 1
Slave control board could not communicate with the cutter control board (it
detected the communication alarm for over 5 sec.).
Slave Control Board defective
Cutter control board defective
Connector loose, broken, defective
Reconnect the connector.
Replace the slave control board.
Replace the cutter control board.
Replace the harness.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Slave-to-cutter control board communication error 2
Cutter control board could not communicate with the slave control board and
detected the communication alarm for over 5 sec.
Slave Control Board defective
Cutter control board defective
Connector loose, broken, defective
Reconnect the connector.
Replace the slave control board.
Replace the cutter control board.